Optimising thickener efficiency - Sustainability Matters

Bed mass is calculated based on the total volume of combined water and solids in the tank and the total hydrostatic pressure measured near the bottom of the tank. As the specific gravity of water is a known constant, the mass of the solid content can be calculated.

Get A Free QuoteLeave your needs

Improving thickener bed density by ultrasonic treatment ...

Improving thickener underflow density will recover more water from tailings' processing and ease the pressure on water demand, reduce tailings storage footprint, maximise capacity of tailings storage facility and minimise the risk of stope barricade failure; therefore, the improved thickener under flow bed density is environmentally and ...

Get A Free QuoteLeave your needs

Outotec Thickening technologies

Outotec® Thickening technologies Leading edge technologies for thickening and clarifying Outotec is a global leader in the design, fabrication ... Bed Level. Outotec High Rate Thickener control Control solution The disturbances can be controlled by means of a

Get A Free QuoteLeave your needs

Pressure Filters | Graver Water Systems

For individual bed areas of 100 square feet or less, the vertical pressure filters are usually furnished. For greater areas, a horizontal pressure filter is more practical. In applications where a large quantity of water is to be filtered, a battery of filters is installed in parallel to provide the necessary throughput.

Get A Free QuoteLeave your needs

Belt filter - Wikipedia

The belt filter (sometimes called a belt press filter, or belt filter press) ... The pressure or wedge zones use two belts, ... In order of increasing cost and decreasing product moisture the most common dewatering options are a thickener, deep bed thickening, ...

Get A Free QuoteLeave your needs

Lamella Clarifier | Graver Water Systems

Industrial Water Treatment Equipment, Condensate Polishing. Clarification, Filtration, Fossil Power, Nuclear Power, NGCC, Combined Cycle Plant

Get A Free QuoteLeave your needs

EIMCO Thickeners strategies-for-instrumentation-and ...

EIMCO Thickeners strategies-for-instrumentation-and-control.pdf - Download as PDF File (.pdf), Text File (.txt) or read online. ... as inputs. the bed-level sensor is represented by a software object with attributes of measured bed position. bed pressure. Table 1 .Thickener strategy measurement and control parameters Process Parameter Process ...

Get A Free QuoteLeave your needs

Advanced Thickener Control - Outotec

Principle of advanced thickener control. UNDERFLOW CONTROL. ... Underflow density, turbidity and bed pressure before and after installation of thickener optimizer. Figure 3. Relative distribution of underflow density before (red) and after (green) installation of thickener optimizer. ...

Get A Free QuoteLeave your needs

Thickeners - Roytec

Roytec has emerged as one of Southern Africa's leading Thickener suppliers. Our advances in feedwell optimization (RadFlow), Drive Head design and Bolted Tank experience has resulted in many significant thickener installations. ... Control systems with bed level, bed pressure, torque and rake elevation ... Our Thickeners are designed using ...

Get A Free QuoteLeave your needs

Thickener Brochure high res-1 - MIP Process

The main components of the thickener/clarifier are the Tank and the Mechanism. Tank ... lifting device is used to raise the rakes above the mud bed if the solids are not removed timeously. Single or multiple lifting ... Hydraulic pressure is used for monitoring rake torque. Three levels of protection exist for the drive mechanism:

Get A Free QuoteLeave your needs

Beginners Guide to Thickeners - Outotec

In practice, with a fixed inventory (bed pressure) the bed expands or contracts depending upon the flocculation effectiveness. INSTRUMENTATION The measurable parameters that can be used for thickener control include thickener feed flow rate, feed density, underflow density, overflow clarity, bed level, bed mass, rake torque, rake height, solids ...

Get A Free QuoteLeave your needs

Improving thickener bed density by ultrasonic treatment ...

Improving thickener underflow density will recover more water from tailings' processing and ease the pressure on water demand, reduce tailings storage footprint, maximise capacity of tailings storage facility and minimise the risk of stope barricade failure; therefore, the improved thickener under flow bed density is environmentally and ...

Get A Free QuoteLeave your needs

THICKENERS AND CLARIFIERS - Roytec

Thickener experience, Roytec is privately owned by ... technologies. Roytec have advanced the development of our Thickeners and Clarifiers to exceed the demands of the modern process plant, in keeping with our goals of reducing overall cost of ownership through technology. ... • Bed pressure measurement. • Feedwell settling rate monitoring.

Get A Free QuoteLeave your needs

Bed Level Detector – Royce Water Technologies

Get more reliable interface level / bed level measurement with the WTW IFL 700 IQ Digital Sensor. Intelligent signal processing with smart filtering.

Get A Free QuoteLeave your needs

Improving thickener bed density by ultrasonic treatment ...

Improving thickener bed density by ultrasonic treatment. ... This technology will be beneficial for tailings' management where the improvement in thickener bed density is environmentally and economically crucial. ... Improving thickener underflow density will recover more water from tailings' processing and ease the pressure on water demand ...

Get A Free QuoteLeave your needs

Concentrate Thickener Bed Level Control

The sonar bed level transmitter is calibrated to monitor and track a specific density in the Thickener. No further calibration is required. Automatic scum cleaning is standard.

Get A Free QuoteLeave your needs

Paste Thickener Bed Level Measurement

Numerous methods have been employed to achieve reliable bed level measurement including bed pressure, ultrasonic, capacitance, nuclear, vibrating probes, divers and floats to name a few. They are typically limited to measuring the level at one location in the thickener and they range from being very expensive to reasonably affordable.

Get A Free QuoteLeave your needs

Current Trends in Countercurrent Decantation and Thickener ...

normal measurements of rake torque, bed pressure and underflow density to understand and operate a CCD or thickener optimally. A photograph of a Smart Diver installed at Gold Fields, St Ives, ... CURRENT TRENDS IN COUNTERCURRENT DECANTATION AND THICKENER CIRCUIT OPERABILITY AND CONTROL ...

Get A Free QuoteLeave your needs

Optimising thickener efficiency - Sustainability Matters

Bed mass is calculated based on the total volume of combined water and solids in the tank and the total hydrostatic pressure measured near the bottom of the tank. As the specific gravity of water is a known constant, the mass of the solid content can be calculated.

Get A Free QuoteLeave your needs

Gravity Thickening of Water-Treatment-Plant Sludges

Thus, the area of the thickener can be evaluated as well as the depth of the thickening zone. The phenomenon called channelling that occurs in the sludge in the thickening zone can be described as ...

Get A Free QuoteLeave your needs

CHAPTER 3 SLUDGE THICKENING - Marmara Üniversitesi

CHAPTER 3 SLUDGE THICKENING Thickening is a procedure used to increase the solids content of sludge by removing a portion of the liquid fraction. To illustrate, if waste activated sludge, which is typically ... The thickener given here will operate successfully as long as the rate of solids applied to the

Get A Free QuoteLeave your needs

Product Applications for the Pulp and Paper Industry

Product Applications for the Pulp and Paper Industry Non contacting, non-intrusive Radiometric and Microwave ... Lime Mud Thickener Application ... from the thickener as well as preventing the bed pressure from

Get A Free QuoteLeave your needs

Thickener optimization to reduce your production costs ...

Thickener optimization to reduce your production costs Integrated online monitoring im-proves concentrator performance Easy monitoring of data from all critical measuring points at a ... Hydraulic pressure, bed height and bed mass are some of the critical measuring points, as well as

Get A Free QuoteLeave your needs

Absolute and gauge pressure - Cerabar PMC51 | Endress+Hauser

The Cerabar PMC51 absolute and gauge pressure transmitter is used for pressure, level, volume or mass measurement in liquids and gases.

Get A Free QuoteLeave your needs

Pulp, paste and putty: thickeners and flocculants for high ...

The compression zone, where the particle settling rate is constrained by mechanical support of the thickener walls and hydraulic pressure or compressive head of overlying slurry and liquor, balanced by underflow withdrawal and upward percolation of water released from the bed.

Get A Free QuoteLeave your needs
Pre: rod mill vs ball millNext: coal mines provident fund organisation formation beyonce